Introduction of Laiest Building II
Location |
No. 338, Ta-Tun 11th Street, Nan-Tun District, Taichung City |
Story | 10F / B2F |
Standard Space |
60 - 72 pings ( 198 - 238 m2 ) per office 197 - 330 pings ( 651 - 1091 m2 ) per floor |
Standard Floor Net Height | 3.6 m per story |
Year of Inauguration |
Year 2005 |
Lobby and First Floor Net Height | 6.2 m |
Structure |
Reinforced Concrete |
Exterior Wall | High compressive strength tile |
Construction Material |
Fireproof construction materials with fireextinguishing system |
Flat-deck Roof | Reinforced concrete |
Floor | Marble floor around every elevator shaft and lobby | Internal Wall |
Reinforced concrete painted with Dulux low-allergy paint Office: Light-weight partition painted with Dulux low-allergy paint Elevator: Marble wall surface Pantry Room & Bathroom: slate tile for wall surface |
Sanitary Equipment |
Each floow is equipped with independent pantry room and bathrooms for males and females | ||
Elevator |
Two Fujitec high-speed elevators ( 205 m/min ) Each with capacity of 12-person One Fujitec high-speed emergency elevators ( 205 m/min ) With capacity of 12-person |
Disaster Protection System |
1. Automatic sprinklers for offices 2. Automatic foam fire extinguishers are installed in the parking lot 3. Automatic fire alarms 4. Automatic smoke exhaust device 5. Emergency Public Address Equipment |
Air-conditioning System |
1. Each office is equipped with independent Hitachi power-saving variable frequency heating & air-conditioning System 2. The bathrooms are equipped with the exhaust ventilation equipment |
Central Monitoring System |
1. 24-hour security guard to safeguard the building occupants 2. The central monitoring system controls the air-conditioning system, power supply, water draining, lighting system and disaster protection system of the building 3. Video cameras are installed in common areas to monitor the building entry and exit 4. The elevators are placed under the control of the central monitoring system; moreover, elevator door access card readers are installed to control the personnel entry and exit |
Emergency Generator |
German MAN 400Kw diesel engine generator is installed The central monitoring system regulates the load and determines the supply priority |
Emergency Lighting System | The emergence lighting system with an illumination of at least 1 Lux is equipped pursuant to the firefighting regulations |
Telecommunication Equipment |
Reserved line and outlet for Chunghwa Telecom fiber-optic communication Reserved line and outlet for Taiwan Fixed Network fiber-optic communication |
Grounding Device |
Each system is separately equipped with the grounding device 1. Grounding device for the telecommunication equipment 2. Grounding device for the light-current system 3. Grounding device for the lightning rod 4. Grounding device for the power equipment |
Parking Lot |
B1F : Ground-type parking lot B2F : Ground-type parking lot |
Landscaping of Common Area | Green Landscaping/Planting of Taiwan White Pine and Japanese cherry blossom; creating a Zen style of Japanese garden design; equipped with automatic artificial fog system |